Asaclean® NCH Grade Extrusion Purging Instructions for Resins 175°C – 360°C (345°F – 680°F)
- Empty the system of the production resin, and make sure the feed areas are clean. Do not remove the die.
- If the changeover or cleaning is known to be difficult, flush the machine by running 1-4 system volumes of clean, natural extrusion grade HDPE.
- Add Asaclean® NCH at normal screw speed until the purge begins to extrude uniformly from the die.
- With the screw turning at minimum controllable rpm, allow for a 5-minute heat soak. Asaclean® NCH is heat activated, so expansion will occur during the heat soak (if sealing, turn off all heaters with the system full of Asaclean® NCH).
- Purge the machine of the Asaclean® NCH.
- If contamination is observed as the last of the Asaclean® NCH leaves the system, repeat steps 3-5.
Note: If increased effectiveness is required, increase temperatures downstream of the extruder and/or increase soak time up to 30 minutes. Do not exceed 360°C (680°F). - If heats have been raised, set temperature profile to the next resin process conditions and, when safe, displace the Asaclean® NCH with the next resin.
- Begin production under normal processing conditions.
Technical Questions?
To request detailed technical bulletins or technical support, contact us at Asahi Kasei Plastics North America Inc.
Phone: (800) 787-4348 / (973)257-1999
Fax: (973) 257-1011
Website: www.Asaclean.com
E-mail: sales@Asaclean.com